Catalog

Hager ADS982D RCD/MCB 1P+N 6kA C32A 0.03A A QB

In stock
SKU: 156218
€70.87
Into a basketIn the basketGo

Overview

Residual current circuit breaker 1P+N 6kA C characteristic 32A 30mA type A QC. Residual current circuit breaker in accordance with DIN0664-20 / EN61009-1 with QuickConnect terminal in accordance with DIN EN 60898-1,0641-11, on the outgoing circuit up to 20A and on the incoming circuit up to 63A, contact protection in accordance with IP2x DIN0106 part 100, external blue test button and residual current display. Easy individual removal from the phase busbar system. With symbol. Suitable for the subsequent installation of additional equipment. Labeling option directly on the device.

Property Value
Trip characteristic: C
Rated current: 32 A
Rated residual current: 0.03 A
Rated voltage: 240 V
Frequency: 50 Hz
Number of poles (total): 2
Width in pitch units: 2
Fault current type: A
Installation depth: 68 mm
Rated breaking capacity according to IEC 60947-2: 6 kA
Surge current strength: 0.25 kA
Degree of protection (IP): IP20
Energy limitation class: 3
Overvoltage category: 3
Pollution degree: 2
Switching neutral conductor: yes
Number of protected poles: 1
Type of voltage: AC
False tripping protection: no
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1: 6 kA
Shutdown characteristic: undelayed
With locking device: yes
Ambient temperature during operation: -25 to 40 °C
Connectable conductor cross-section, single-wire: 1 to 25 mm²
Connectable conductor cross-section, stranded: 1 to 16 mm²

Characteristics

Shutdown characteristicsWithout delay
Rated short-circuit breaking capacity Icn according to EN 61009-16 kA
ManufacturerHAGER
HANADS982D
GTIN3250611068259
Connectable conductor cross-section solid1 to 25 mm²
Connectable conductor cross-section stranded1 to 16 mm²
Number of protected poles1
Trigger characteristicsC
Rated breaking capacity according to IEC 60947-26kA
Rated residual current0.03A
Rated insulation voltage Ui500V
Rated voltage240V
Rated impulse withstand voltage Uimp4kV
Rated current32 A
Width in pitch units2
Installation depth68 mm
Energy limitation class3
False trigger protectionNo
Residual current typeA
Frequency50Hz
With locking deviceYes
Switching neutral conductorYes
Number of poles (total)2
IP protection)IP20
Voltage typeAC
Surge current strength0.25kA
Ambient temperature during operation-25 to 40 °C
Degree of contamination2
Overvoltage category3
Hager ADS982D RCD/MCB 1P+N 6kA C32A 0.03A A QB
Hager ADS982D RCD/MCB 1P+N 6kA C32A 0.03A A QB
€70.87
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart