Catalog

Hager ADX410D FI/LS switch 4-pole 10kA B10A 0.03A A

In stock
SKU: 303509
€230.52
Into a basketIn the basketGo

Overview

Residual current circuit breaker 4P 10kA B-10A 30mA A Typ. Residual current circuit breaker according to DIN0664-20 / EN61009-1 with 4-pole circuit breaker for 400 V three-phase circuits and a residual current protection circuit in a compact housing. Contact protection according to IP2x according to DIN0106 Part 100, blue test button and residual current display. Easy individual removal from the phase busbar system. With VDE symbol. Suitable for the subsequent installation of additional equipment. Labeling option directly on the device.

Property Value
Triggering characteristic: B
Rated current: 10 A
Rated residual current: 0.03 A
Rated voltage: 400 V
Frequency: 50 Hz
Number of poles (total): 4
Width in pitch units: 4
Fault current type: A
Installation depth: 70 mm
Surge current strength: 3 kA
Protection class (IP): IP20
Energy limitation class: 3
Overvoltage category: 3
Pollution degree: 2
Switching neutral conductor: no
Number of protected poles: 4
Type of voltage: AC
False tripping protection: no
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1: 10 kA
Shutdown characteristics: undelayed
With locking device: yes
Ambient temperature during operation: -25 to 40 °C
Connectable conductor cross-section, single-wire: 1 to 25 mm²
Connectable conductor cross-section, stranded: 1 to 16 mm²

Characteristics

Shutdown characteristicsWithout delay
Rated short-circuit breaking capacity Icn according to EN 61009-110 kA
ManufacturerHAGER
HANADX410D
GTIN3250611016946
Connectable conductor cross-section solid1 to 25 mm²
Connectable conductor cross-section stranded1 to 16 mm²
Number of protected poles4
Trigger characteristicsB
Rated residual current0.03A
Rated insulation voltage Ui500V
Rated voltage400V
Rated impulse withstand voltage Uimp4kV
Rated current10A
Width in pitch units4
Installation depth70 mm
Energy limitation class3
False trigger protectionNo
Residual current typeA
Frequency50Hz
With locking deviceYes
Switching neutral conductorNo
Number of poles (total)4
IP protection)IP20
Voltage typeAC
Surge current strength3kA
Ambient temperature during operation-25 to 40 °C
Degree of contamination2
Overvoltage category3
Hager ADX410D FI/LS switch 4-pole 10kA B10A 0.03A A
Hager ADX410D FI/LS switch 4-pole 10kA B10A 0.03A A
€230.52
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart