Staircase light timer 230V. 1 normally open contact not potential-free 10A/250V AC, incandescent lamps up to 2000W, ESL and LED lamps up to 200W, switch-off warning and push-button permanent light can be switched on. Standby loss only 0.7 watts. With ESL optimization. For built-in installation. 45mm long, 45mm wide, 18mm deep. Contact switching at zero crossing to protect the contacts and lamps.
In particular, this extends the service life of energy-saving lamps. By using a bistable relay, there is no coil power loss and no heating as a result, even when switched on. After installation, wait for the automatic short synchronization before connecting the switched consumer to the mains. Control, supply and switching voltage 230V. Time setting 1 to 12 minutes. Glow lamp current up to 50mA, depending on the ignition voltage of the glow lamps. For 3- and 4-wire circuits, can be switched on later, with attic lighting with 4-wire circuits. Automatic detection of the circuit type. After a power failure, the lighting is switched back on if the time period has not yet expired.
If the switch-off warning function is switched on, the lighting flickers starting around 30 seconds before the time period expires and a total of 3 times at increasingly shorter intervals. If the permanent light button is switched on, the light can be set to permanent light by pressing the button for longer than 1 second, which switches off automatically after 60 minutes, or it can be switched off by pressing the button for longer than 2 seconds. If the permanent light button and switch-off warning function are switched on, the switch-off warning only occurs after the permanent light is switched off. If energy-saving lamps ESL are switched on in whole or in part, then set the switch-off warning with the permanent light button ESL on the lower rotary switch.
Within the first second after switching on or switching on again, the time can be extended with the TLZ functions by briefly pressing the button up to three times (pumping). Each press adds the set time once. Can be switched to the ESV function, impulse switch with release delay of up to 120 minutes. In this function, the device switches off automatically after the adjustable delay time has elapsed if the manual off command has not been given. If the delay time is set to minimum in the ESV function, the release delay is switched off and the normal impulse switch function ES is used.
Property | Value |
Release delay: | 1 to 12 min |
Function: | electronic with switch-off warning |
Mounting type: | Flush-mounted |
Control voltage 1: | 230 V |
Rated switching current: | 10 A |
Control voltage type 1: | AC |
Current surge function selectable: | no |
Frequency of control voltage 1: | 50 Hz |
Circuit type: | 3- and 4-wire circuit |
Switch-off warning: | flickering |
Follow-up switching: | can be switched on again + continuous light + time extension |
Type of supply voltage: | AC |
Installation depth: | 18 mm |
Button glow lamp current: | 50 mA |
Supply voltage: | 250 V |
Max. incandescent lamp load: | 2000 W |
Max. fluorescent lamp load: | 1000 VA |
Max. fluorescent lamp load (duo circuit): | 1000 VA |
Max. Fluorescent lamp load (parallel compensated): | 500 VA |
Number of contacts as normally open: | 1 |