Residual current/current-operated circuit breakers (RCBOs) offer protection for people and property as well as protection against electrically ignited fires in accordance with DIN0100-410 and DIN0100-530. They ensure protection of single-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with smooth DC residual current of up to 10 mA against earth. As well as fault protection (protection against indirect contact), additional protection (with I n 30 mA) and fire protection (with I n 300 mA). They have a higher insensitivity to unwanted triggering due to a short-time delay and can detect mixed frequency currents up to 1 kHz. They meet the product standard IEC/EN 61009-1 (VDE 0664-20). Contact is made directly via the Smissline TP plug-in base system and the outer conductor contact can be freely selected for single-phase devices (L1, L2 or L3)

PropertyValue
Tripping characteristic:C
Rated current:25 A
Rated residual current:0.03 A
Rated voltage:240 V
Frequency:50/60 Hz
Number of poles (total):2
Width in modular spacing:2
Residual current type:A
Installation depth:91 mm
Rated breaking capacity according to IEC 60947-2:10 kA
Surge current strength:3 kA
Protection class (IP):IP20
Energy limitation class:3
Overvoltage category:3
Pollution degree:2
Switching neutral conductor:yes
Number of protected poles:1
Suitable for flush-mounted installation:no
Voltage type:AC
False tripping protection:yes
Rated insulation voltage Ui:500 V
Rated impulse withstand voltage Uimp:4 kV
Rated breaking capacity according to EN 61009:10 kA
Rated short-circuit breaking capacity Icn according to EN 61009-1:10 kA
Shutdown characteristics:short-time delayed
With locking device:yes
Ambient temperature during operation:-25 to 40 °C
Connectable conductor cross-section, single-wire:0.75 to 35 mm²
Connectable conductor cross-section, stranded:0.75 to 35 mm²

Characteristics

Shutdown characteristicsShort-term delayed
Rated short-circuit breaking capacity Icn according to EN 61009-110 kA
HABC32A 400VAC 30mA 10kA 2P
ManufacturerABB Stotz-Kontakt
HAN2CCL562310E1254
GTIN7612271472986
Connectable conductor cross-section solid0.75 to 35 mm²
Connectable conductor cross-section stranded0.75 to 35 mm²
Number of protected poles1
Trigger characteristicsC
Rated breaking capacity according to EN 6100910kA
Rated breaking capacity according to IEC 60947-210kA
Rated residual current0.03A
Rated insulation voltage Ui500V
Rated voltage240V
Rated impulse withstand voltage Uimp4kV
Rated current25A
Width in pitch units2
Installation depth91 mm
Energy limitation class3
False trigger protectionYes
Residual current typeA
Frequency50/60Hz
Suitable for flush-mounted installationNo
With locking deviceYes
Switching neutral conductorYes
Number of poles (total)2
IP protection)IP20
Voltage typeAC
Surge current strength3kA
Ambient temperature during operation-25 to 40 °C
Degree of contamination2
Overvoltage category3
ABB Stotz-Kontakt 2CCL562310E1254 C32A 400VAC 30mA 10kA 2P residual current circuit breaker
ABB Stotz-Kontakt 2CCL562310E1254 C32A 400VAC 30mA 10kA 2P residual current circuit breaker
€225.50
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart