Residual current circuit breakers (RCCBs) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN0100-410 and DIN0100-530. The residual current circuit breakers of the F200 series ensure protection against sinusoidal alternating currents and pulsating currents to earth. As well as fault protection (protection against indirect contact), additional protection (with I n 30 mA) and fire protection (with I n 300 mA). They meet the product standards IEC/EN 61008-1, 61008-2-1, 61543 (VDE 0664 10, 11, 30) and for F200 A to 100 A UL 1053. Areas of application are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous approvals make the F200 suitable for worldwide use. Optimum compromise between safety and operational continuity thanks to the interference immunity against unwanted triggering with surge current resistance (surge current form 8/20 s) = 5000 A. Selectivity with downstream devices with a smaller rated residual current of e.g. 30 mA (see selectivity tables in the catalog, chapter Technology).

PropertyValue
Rated voltage:400 V
Rated current:125 A
Mounting type:DIN rail
Protection class (IP):IP20
Frequency:50 Hz
Number of poles:4
Width in pitch units:4
Selective type:no
Residual current type:A
Additional equipment possible:yes
Installation depth:69 mm
Short-time delayed type:no
Rated insulation voltage Ui:500 V
Rated impulse withstand voltage Uimp:4 kV
With locking device:no
Ambient temperature during operation:-25 to 40 °C
Pollution degree:2
Connectable conductor cross-section, single-wire:50 to 1.5 mm²

Characteristics

HABF204AS-125/0.3L 4-pin
ManufacturerABB Stotz-Kontakt
HAN2CSF204223R3950
GTIN8012542968306
Connectable conductor cross-section solid50 to 1.5 mm²
Rated insulation voltage Ui500V
Rated voltage400V
Rated impulse withstand voltage Uimp4kV
Rated current125A
Width in pitch units4
Installation depth69 mm
Residual current typeA
Frequency50Hz
Short-time delayed typeNo
With locking deviceNo
Mounting typeDIN rail
Number of poles4
IP protection)IP20
Selective typeNo
Ambient temperature during operation-25 to 40 °C
Degree of contamination2
Additional equipment possibleYes
ABB Stotz-Kontakt 2CSF204223R3950 F204AS-125/0.3L 4-pole residual current circuit breaker
ABB Stotz-Kontakt 2CSF204223R3950 F204AS-125/0.3L 4-pole residual current circuit breaker
€1,706.29
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart