Catalog

ABB Stotz-Kontakt DDA803 A-100/0.03 AP-R, DDA803A-100/0.03 AP-R FI-Block for S803 3P Type A 100A 30mA short-time delayed, 2CSB803401R1000

In stock
SKU: 203352
€434.01
Into a basketIn the basketGo

Overview

The residual current block (RCU) is designed for customer-side assembly with high-performance automatic circuit breakers from the S800 series. The resulting residual current/circuit breaker combinations (RCBOs) offer property protection as well as protection against electrically ignited fires. They ensure protection of 2P, 3P or 4P circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA against earth. As well as fault protection (protection against indirect contact), additional protection (with I n 30 mA) and fire protection (with I n 300 mA). They meet the product standard IEC/EN 60947-2. Areas of application are industrial applications. The extensive range of accessories offers you everything you need for your installation tasks., Optimal compromise between safety and operational continuity thanks to the interference immunity with surge current resistance (surge current form 8/20 s) = 3,000 A against unwanted triggering and 10 ms short-time delay.

PropertyValue
Nominal voltage:230 to 400 V
Delay time adjustable:no
Rated residual current adjustable:no
Nominal current:100 A
Residual current type:A
Number of poles:3
Rated residual current:0.03 A
Surge current strength:3 kA
Frequency:50/60 Hz
Rated insulation voltage Ui:690 V
Rated impulse withstand voltage Uimp:6 kV
Connectable conductor cross-section, single-wire:6 to 70 mm²
Connectable conductor cross-section, stranded:6 to 50 mm²
False tripping protection:yes
With locking device:no
Protection class (IP):IP2X
Ambient temperature during operation:-25 to 60 °C

Characteristics

HABDDA803 A-100/0.03 AP-R
ManufacturerABB Stotz-Kontakt
HAN2CSB803401R1000
GTIN8012542542230
Connectable conductor cross-section solid6 to 70 mm²
Connectable conductor cross-section stranded6 to 50 mm²
Rated residual current0.03A
Rated insulation voltage Ui690V
Rated impulse withstand voltage Uimp6kV
False trigger protectionYes
Residual current typeA
Frequency50/60Hz
With locking deviceNo
Nominal voltage230 to 400 V
Rated current100A
Number of poles3
IP protection)IP2X
Surge current strength3kA
Ambient temperature during operation-25 to 60 °C
ABB Stotz-Kontakt DDA803 A-100/0.03 AP-R, DDA803A-100/0.03 AP-R FI-Block for S803 3P Type A 100A 30mA short-time delayed, 2CSB803401R1000
ABB Stotz-Kontakt DDA803 A-100/0.03 AP-R, DDA803A-100/0.03 AP-R FI-Block for S803 3P Type A 100A 30mA short-time delayed, 2CSB803401R1000
€434.01
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart