Catalog

ABB Stotz-Kontakt F-ATI2Test A-25/0.03, F-ATI2Test A-25/0.03 residual current circuit breaker 5TE 2P, type A, 25A, 30mA, short-time delay, FIauto.Test, 2CSF302130R1250

In stock
SKU: 321677
€604.44
Into a basketIn the basketGo

Overview

F-ATI and F-ARI are RCCBs with an automatic uninterruptible test function. Depending on the application, RCCBs should be tested at least every six months. This ensures that the contacts are functioning properly and that the device is tripped in the event of a fault current to earth. Regular testing of RCCBs affects the uninterrupted operation of the downstream circuits and is associated with a great deal of work. When using F-ATI and F-ARI, this work is eliminated. These FIs carry out the regular tests automatically and without interrupting the system. Operation by maintenance personnel can therefore be reduced to a minimum. In addition to the automatic tests, the F-ARI series is equipped with an automatic reclosing unit to close the RCCB again after it has been tripped. This is specifically designed for areas to which only electrically trained persons or qualified electricians have access. Restart is based on an insulation test to ensure that it is not a permanent fault. The results of all circuits are also collected via the ARBus interface.

PropertyValue
Rated current:25 A
Number of poles:2
Rated residual current:0.03 A
Width in modular spacing:5
Short-time delayed type:yes
Size (according to DIN 43880):5
Protection class (IP):IP20
Additional devices integrated:Self-test, automatic restart and auxiliary switch
Mounting type:DIN rail
Rated switching current of additional device:0.1 A
Fault current type:A
Rated voltage:230 V
Installation depth:80 mm
Rated voltage of additional device:230 V
Frequency:50 Hz
Control voltage type of additional device:AC/DC
Selective type:no

Characteristics

HABF-ATI2Test A-25/0.03
ManufacturerABB Stotz-Kontakt
HAN2CSF302130R1250
GTIN8012542288855
Rated residual current0.03A
Rated voltage230V
Rated current25A
Width in pitch units5
Installation depth80 mm
Residual current typeA
Frequency50Hz
Short-time delayed typeYes
Mounting typeDIN rail
Number of poles2
IP protection)IP20
Selective typeNo
ABB Stotz-Kontakt F-ATI2Test A-25/0.03, F-ATI2Test A-25/0.03 residual current circuit breaker 5TE 2P, type A, 25A, 30mA, short-time delay, FIauto.Test, 2CSF302130R1250
ABB Stotz-Kontakt F-ATI2Test A-25/0.03, F-ATI2Test A-25/0.03 residual current circuit breaker 5TE 2P, type A, 25A, 30mA, short-time delay, FIauto.Test, 2CSF302130R1250
€604.44
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart