ABB Stotz-Kontakt S802U-Z15, high-performance circuit breaker, 15A,Z,240VAC=Icu 50kA,2P, UL 489, 2CCS862017R0155

In stock
SKU: 198964
€248.73
Into a basketIn the basketGo

Overview

The high-performance circuit breakers in the S800U series protect cables and lines against overload and short circuits. They have a rated short-circuit breaking capacity of 50kA at 240/415V AC. In addition, it can be used for voltages up to 240V AC according to UL489 with a breaking capacity of 50kA. With its thermal tripping mechanism, it offers equally effective protection against overload, as does its electromechanical tripping mechanism against short circuits. The S800U complies with the IEC/EN 60947-2 and UL489 standards and can be used for industrial purposes. Numerous approvals make it suitable for use worldwide and the extensive range of accessories makes it even more convenient to use. Thanks to the very fast arc extinguishing, your installation is optimally protected with the S800U.

PropertyValue
Tripping characteristic:Z
Rated current:15 A
Rated voltage:240 V
Type of voltage:AC
Frequency:50 to 60 Hz
Width in modular spacing:3
Number of poles (total):2
Energy limitation class:3
Additional equipment possible:yes
Overvoltage category:3
Installation depth:82.5 mm
Protection class (IP):IP20
Rated switching capacity Icn according to EN 60898 at 230 V:40 kA
Rated switching capacity Icu according to IEC 60947-2 at 230 V:50 kA
Pollution level:2
Switching neutral conductor:no
Number of protected poles:2
Suitable for flush-mounted installation:no
Rated insulation voltage Ui:690 V
Rated impulse withstand voltage Uimp:8 kV
Ambient temperature during operation:-25 to 60 °C
Connectable conductor cross-section, stranded:0 to 70 mm²
Connectable conductor cross-section, solid:0 to 50 mm²

Characteristics

HABS802U-Z15
ManufacturerABB Stotz-Kontakt
HAN2CCS862017R0155
GTIN7612271214531
Connectable conductor cross-section solid0 to 50 mm²
Connectable conductor cross-section stranded0 to 70 mm²
Number of protected poles2
Trigger characteristicsZ
Rated insulation voltage Ui690V
Rated switching capacity Icn according to EN 60898 at 230 V40kA
Rated switching capacity Icu according to IEC 60947-2 at 230 V50kA
Rated voltage240V
Rated impulse withstand voltage Uimp8kV
Rated current15A
Width in pitch units3
Installation depth82.5 mm
Energy limitation class3
Frequency50 to 60 Hz
Suitable for flush-mounted installationNo
Switching neutral conductorNo
Number of poles (total)2
IP protection)IP20
Voltage typeAC
Ambient temperature during operation-25 to 60 °C
Degree of contamination2
Additional equipment possibleYes
Overvoltage category3
ABB Stotz-Kontakt S802U-Z15, high-performance circuit breaker, 15A,Z,240VAC=Icu 50kA,2P, UL 489, 2CCS862017R0155
ABB Stotz-Kontakt S802U-Z15, high-performance circuit breaker, 15A,Z,240VAC=Icu 50kA,2P, UL 489, 2CCS862017R0155