Catalog

Doepke 09134988HD DFS4 040-4/0,03-B SK R HD zero line right residual current circuit breaker all-current sensitive

In stock
SKU: 707193
€383.73
Into a basketIn the basketGo

Overview

Residual current circuit breakers (RCCB) switch off the power supply when dangerously high residual currents occur. They thus protect people, animals and systems. DFS 4 are two- or four-pole residual current circuit breakers for single- or three-phase networks. In the standard version, the compact devices are four division units wide. They are available with many different residual current types and versions with rated currents of up to 125 A. The large double-deck terminals can also accommodate large conductor cross-sections. The tripped position of the multi-function switch toggle makes troubleshooting easier. The free label software helps with labeling. Type B switches are universally sensitive at frequencies from 0 Hz (smooth DC residual currents) to 150 kHz. They are resistant to increased surge currents and storms. SK series residual current circuit breakers stand for residual current protection and high system availability. They are characterized by a lower response sensitivity at higher frequencies. The SK characteristic curve is optimized for systems in which no fire protection is required. Standard devices are designed for monitoring circuits with a rated voltage of 230 V/400 V and a rated frequency of 50 Hz. With an airtight encapsulated release made of a special alloy and the stainless steel switch lock, residual current circuit breakers in HD design are particularly protected against corrosion, harmful gases, moisture and strong temperature fluctuations. Properties: high immunity to operational leakage and fault currents at frequencies from 1 kHz, meets the requirements of the building regulations 0664-10, 0664-40, ÖVE/ÖNORM E 8601, universal current sensitive for fault currents with frequencies and mixed frequencies from 0 Hz (smooth direct current) to 150 kHz, electromagnetic compatibility in accordance with 0664-30 and 0839-6-2 (interference immunity for industrial applications), mains voltage-independent tripping for fault currents of type A, voltage-dependent detection of smooth direct fault current and alternating fault currents with frequencies other than 50/60 Hz, full functionality with mains voltages from at least 50 V AC on any two active conductors, small size for all rated currents, high short-circuit strength, double-sided double-deck terminals for large conductor cross-sections and rail connection, switch position indicator, viewing window for labels, multifunctional switch toggle with three Positions: 'on', 'off', 'triggered', connection C1 neutral conductor position on the right, mounting type: quick fastening on mounting rail, installation position as desired, feed-in preferably from above, areas of application: commercial and industrial installations with TN-S, TT and TN-CS systems in which power electronics equipment without galvanic mains isolation is used, such as frequency converters, switched-mode power supplies, high-frequency power converters. Photovoltaic and UPS systems with transformerless inverters, notes: suitable for use in 50 Hz alternating current networks, RCCB for other frequencies on request, not intended for use in direct current networks or on the output side of controlled electrical equipment such as frequency converters.

PropertyValue
Rated voltage:400 V
Rated current:40 A
Rated residual current:0.03 mA
Mounting type:DIN rail
Protection class (IP):IP20
Frequency:50 Hz
Number of poles:4
Width in pitch units:4
Selective type:no
Residual current type:B
Additional equipment possible:yes
Installation depth:69 mm
Short-circuit strength (Icw):10 kA
Surge current strength:3 kA
Short-time delayed type:yes
Rated insulation voltage Ui:400 V
Rated impulse withstand voltage Uimp:4 kV
With locking device:yes
Ambient temperature during Operating:-25 to 60 °C
Pollution level:2
Connectable conductor cross-section, stranded:1.5 to 50 mm²
Connectable conductor cross-section, single-wire:1.5 to 50 mm²

Characteristics

HABDFS4 040-4/0,03-B SK R HD Zero line Right
ManufacturerDOEPKE
HAN09134988HD
GTIN4014712213616
Connectable conductor cross-section solid1.5 to 50 mm²
Connectable conductor cross-section stranded1.5 to 50 mm²
Rated residual current0.03mA
Rated insulation voltage Ui400V
Rated voltage400V
Rated impulse withstand voltage Uimp4kV
Rated current40A
Width in pitch units4
Installation depth69 mm
Residual current typeB
Frequency50Hz
Short circuit strength (Icw)10kA
Short-time delayed typeYes
With locking deviceYes
Mounting typeDIN rail
Number of poles4
IP protection)IP20
Selective typeNo
Surge current strength3kA
Ambient temperature during operation-25 to 60 °C
Degree of contamination2
Additional equipment possibleYes
Doepke 09134988HD DFS4 040-4/0,03-B SK R HD zero line right residual current circuit breaker all-current sensitive
Doepke 09134988HD DFS4 040-4/0,03-B SK R HD zero line right residual current circuit breaker all-current sensitive
€383.73
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart