Residual current circuit breakers (RCCBs) switch off the power supply when dangerously high residual currents occur. They thus protect people, animals and systems. DFS 4 are two- or four-pole residual current circuit breakers for single- or three-phase networks. In the standard version, the compact devices are four division units wide. They are available with many different residual current types and versions with rated currents of up to 125 A. The large double-deck terminals can also accommodate large conductor cross-sections. The tripped position of the multi-function switch toggle makes troubleshooting easier. The free label software helps with labeling. Type A switches are sensitive to pulse and alternating current. This function is independent of the mains voltage. Version V devices are designed for special voltages. Standard version devices are designed for monitoring circuits with a rated frequency of 50 Hz. Properties: tripping independent of mains and auxiliary voltage, sensitive for alternating and pulsating direct residual currents (type A), small size for all rated currents, high short-circuit strength, double-sided double-deck terminals for large conductor cross-sections and rail connection, switch position indicator, viewing window for labels, multi-function switch toggle with three positions: 'on', 'off', 'tripped', connection C1 neutral conductor position on the left, mounting type: quick fastening on mounting rail, installation position as desired, feed direction as desired, areas of application: power supplies for residential and commercial buildings as well as industrial plants with TN-S, TT and TN-CS networks. In IT networks, residual current circuit breakers from this series can be provided for shutdown in the event of a second fault. Use in TN-C networks and to protect systems in which electronic equipment can cause smooth direct residual currents or residual currents with frequencies other than 50 Hz is excluded. Comprehensive protection is not provided here. For such applications, we recommend our all-current sensitive residual current circuit breakers (type B or B+).

PropertyValue
Rated voltage:500 V
Current:80 A
Leakage current:0.03 A
Mounting type:DIN rail
Protection class (IP):IP20
Frequency:50 Hz
Number of poles:4
TE:4
Selective type:no
Residual current type:A
Additional equipment possible:yes
Installation depth:69 mm
Short-circuit strength (Icw):10 kA
Short-time delayed type:no
Rated insulation voltage Ui:500 V
Rated impulse withstand voltage Uimp:4 kV
With locking device:yes
Ambient temperature during operation:-25 to 40 °C
Pollution level:2
Connectable conductor cross-section, stranded:1.5 to 50 mm²
Connectable conductor cross-section, single-wire:1.5 to 50 mm²
Voltage type:AC
Explosion-proof:no

Characteristics

HABDFS4 080-4/0,03-A V500
ManufacturerDOEPKE
HAN09154945
GTIN4014712145429
Connectable conductor cross-section solid1.5 to 50 mm²
Connectable conductor cross-section stranded1.5 to 50 mm²
Rated insulation voltage Ui500V
Rated voltage500V
Rated impulse withstand voltage Uimp4kV
Installation depth69 mm
Explosion-proofNo
Residual current typeA
Frequency50Hz
Short circuit strength (Icw)10kA
Short-time delayed typeNo
With locking deviceYes
Mounting typeDIN rail
Number of poles4
IP protection)IP20
Selective typeNo
Voltage typeAC
TE4
Ambient temperature during operation-25 to 40 °C
Degree of contamination2
Additional equipment possibleYes
Doepke 09154945 DFS4 080-4/0.03-A V500 residual current circuit breaker
Doepke 09154945 DFS4 080-4/0.03-A V500 residual current circuit breaker
€1,007.35
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart