Catalog

Doepke 09219783 DFL8 250-4/X - B NK circuit breaker

In stock
SKU: 324142
€3,790.29
Into a basketIn the basketGo

Overview

Circuit breakers with residual current protection (CBR) switch high currents, protect equipment, cables and lines from overcurrent and people from electric shock. DFL 8 are compact devices with an integrated auxiliary switch and connection terminals for large cable cross-sections. Type B switches are sensitive to all currents. They protect against pulse and alternating residual currents, residual currents with mixed frequencies and smooth direct residual currents at frequencies up to 150 kHz. They are resistant to increased surge currents and storms. Switches with the NK characteristic curve offer classic fire protection of 300 mA at frequencies up to 150 kHz. They are optimized for fire-prone premises. With switches of this variant, the fault response current can be individually set in stages to suit the respective application (0.30 A, 0.50 A, 1.00 A). The non-response time limit can also be set in stages accordingly. This makes it possible to implement a selective residual current protection circuit in systems with staggered distributions. Standard devices are designed for monitoring circuits with a rated voltage of 230 V/400 V and a rated frequency of 50 Hz. Properties: - adjustable rated residual current - rated currents from 100A to 250A, - rated voltage 230 V, 400 V AC, - four-pole, - residual current detection for smooth direct current as well as alternating and pulsating direct currents, - high tolerance to fluctuations in the auxiliary voltage when detecting residual currents type B, - mains and auxiliary voltage independent tripping for residual currents of type A and in the event of overcurrent, - high short-circuit switching capacity, - connection terminals up to 185mm - high surge current strength, i.e. low tendency to false tripping due to transient residual currents - thresholds for instantaneous and delayed overcurrent tripping adjustable - auxiliary switch integrated Mounting type: - attachment to mounting plate - installation position as desired - feed from below Application areas: - staggered power supply systems with TN-S, TT and TN-CS networks with high short-circuit power in commercial buildings and industry - In IT networks, the residual current tripping of the CBR can be provided for switching off in the event of a second earth fault. - Due to its universal current sensitive residual current tripping, this universal current sensitive CBR is particularly suitable for protecting systems with electronic equipment that is not galvanically isolated from the mains on the input side. - It cannot be used for residual current protection in TN-C networks. Notes: - Fire protection with setting I n = 0.3 A up to 100 kHz

PropertyValue
Tripping characteristics:other
Rated current:250 A
Rated residual current:0.3 A
Rated voltage:400 V
Frequency:50 Hz
Number of poles (total):4
Residual current type:B
Installation depth:149 mm
Rated breaking capacity according to IEC 60947-2:85 kA
Surge current strength:5 kA
Protection class (IP):IP20
Overvoltage category:3
Pollution level:3
Switching neutral conductor:yes
Number of protected poles:3
Voltage type:AC
False tripping protection:no
Rated impulse withstand voltage Uimp:4 kV
Shutdown characteristic:short-time delayed
With locking device:yes
Ambient temperature during operation:-25 to 70 °C
Connectable conductor cross-section, single-wire:4 to 16 mm²
Connectable conductor cross-section, stranded:25 to 185 mm²

Characteristics

Shutdown characteristicsShort-term delayed
HABDFL8 250-4/X - B NK
ManufacturerDOEPKE
HAN09219783
GTIN4014712153639
Connectable conductor cross-section solid4 to 16 mm²
Connectable conductor cross-section stranded25 to 185 mm²
Number of protected poles3
Trigger characteristicsOther
Rated breaking capacity according to IEC 60947-285kA
Rated residual current0.3A
Rated voltage400V
Rated impulse withstand voltage Uimp4kV
Rated current250A
Installation depth149 mm
False trigger protectionNo
Residual current typeB
Frequency50Hz
With locking deviceYes
Switching neutral conductorYes
Number of poles (total)4
IP protection)IP20
Voltage typeAC
Surge current strength5kA
Ambient temperature during operation-25 to 70 °C
Degree of contamination3
Overvoltage category3
Doepke 09219783 DFL8 250-4/X - B NK circuit breaker
Doepke 09219783 DFL8 250-4/X - B NK circuit breaker
€3,790.29
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart