Catalog

Doepke 09442502 DRCCB 5 ST 063-4/0.3-A residual current circuit breaker

In stock
SKU: 442632
€611.19
Into a basketIn the basketGo

Overview

Residual current circuit breakers (RCCB) switch off the power supply when dangerously high fault currents occur. In this way they protect people, animals and systems. Devices in the DRCCB 5 series are compact two-pole or four-pole residual current circuit breakers with a self-test function. Type A switches are sensitive to pulse and alternating current. This function is independent of the mains voltage. Self-test (ST) switches regularly and automatically carry out a function test of the residual current circuit breaker. This takes place for the system without interruption and without additional wiring, as the required power supply is integrated. Properties: - monthly self-test, - signaling of the operating status via LEDs, - configurable auxiliary contact Mounting type: - quick attachment to a mounting rail - installation position as required - feed-in from above Areas of application: - the devices are used wherever electrical systems must not be switched off or are difficult to access. This can be, for example, B. IT systems or telecommunications systems, agricultural operations, small wind turbines or sewage treatment plants. - Using an optional Modbus interface module, the switching state of the RCCB can be transmitted for remote monitoring.

PropertyValue
Rated current:63 A
Number of poles:4
Rated residual current:0.3 A
Width in modular spacing:7
Surge current strength:3 kA
Short-time delayed type:yes
Rated breaking capacity:0.63 kA
Protection class (IP):IP20
Additional devices integrated:other
Mounting type:DIN rail
Rated switching current of additional device:63 A
Fault current type:A
Rated voltage:400 V
Installation depth:66.1 mm
Rated voltage of additional device:400 V
Frequency:50 Hz
Control voltage type of additional device:AC
Additional devices fitted at the factory:Monitoring unit
Short-circuit strength (Icw):10 kA
Selective type:no

Characteristics

Rated breaking capacity0.63 kA
ManufacturerDOEPKE
HAN09442502
GTIN4014712238336
Rated residual current0.3A
Rated voltage400V
Rated current63 A
Width in pitch units7
Installation depth66.1 mm
Residual current typeA
Frequency50Hz
Short circuit strength (Icw)10kA
Short-time delayed typeYes
Mounting typeDIN rail
Number of poles4
IP protection)IP20
Selective typeNo
Surge current strength3kA
Doepke 09442502 DRCCB 5 ST 063-4/0.3-A residual current circuit breaker
Doepke 09442502 DRCCB 5 ST 063-4/0.3-A residual current circuit breaker
€611.19