Eltako 28465715 DSZ14DRSZ-3x80A RS485 two-way bus three-phase meter

In stock
SKU: 919141
€187.32
Into a basketIn the basketGo

Overview

RS485 bus two-way three-phase meter. Maximum current 3x80A, standby loss only 0.8 watts at L1 and 0.5W each at L2 and L3. Modular device for mounting on DIN-EN 60715 TH35 mounting rail in installation cabinets with protection class IP51. 4 division units = 70mm wide, 58mm deep. Accuracy class B (1%). With RS485 interface. The direct measuring three-phase meter measures the active energy based on the currents flowing between the inputs and outputs. The self-consumption of only 0.8 watts or 0.5W active power per path is not measured and not displayed. The active energy is added depending on the sign. Positive power in the meter means energy consumption, negative power means energy supply. The energy measurement is carried out on a balancing basis. If the energy consumption (P positive) is greater than the energy supply (P negative), the meter reading T arrow to the right is increased. If the energy supply is greater than the energy consumption, the meter reading T arrow to the left is increased. Energy consumption is shown with a right arrow and energy supply is shown with a left arrow above the active bar in the display. 1, 2 or 3 external conductors with currents of up to 80A can be connected. The starting current is 4OmA. The L1 and N connections must be present. Connection via an FBA14 to the Eltako RS485 bus with a 2-core shielded bus cable (e.g. telephone line). The meter reading and the instantaneous power are transferred to the bus - e.g. for forwarding to an external computer or Professional Smart Home Controller - and also sent to the radio network via the FAM14. For this, a device address must be assigned by the FAM14 radio antenna module, as described in the operating instructions. Energy consumption and energy delivery are stored in a non-volatile manner and are immediately displayed again after a power failure. The 7-segment LC display can be read twice within two weeks even without a power supply. The power consumption is shown with an LED next to the display that flashes 1000 times per kWh. To the right of the display are the MODE and SELECT buttons, which are used to scroll through the menu according to the operating instructions. First, the background lighting switches on. Then the total active energy per consumption and delivery, the active energy of the resettable storage consumption and delivery as well as the instantaneous values of power, voltage and current per phase conductor can be displayed. Error message: If the outer conductor is missing, the corresponding outer conductor is shown in the display.

Property Value
Width in division units: 4
Calibrated: yes
Pole type: Four-wire
Meter type: electronic
Display type: digital
Mounting type: REG
Accuracy class: B
Maximum current (Imax): 80 A
Nominal voltage (Un) NL: 230 V
Protection class (IP): IP20
Frequency: 50 Hz
Tariff version: Two-tariff
Tariff control: external
Energy type: Active power
Nominal current (In): 10 A
Design: Direct measurement
Nominal voltage (Un) LL: 400 V
Number of digits: 7
Suitable for: Reference
Approval: Measuring Instruments Directive
Pulse output: electrical
Interface design: RS-485

Characteristics

Maximum current (Imax)80 A
Accuracy classB
HABDSZ14DRSZ-3x80A RS485 two-way
ManufacturerELTAKO
HAN28465715
GTIN4010312501887
VersionDirect measurement
Implementation of the interfaceRS-485
Width in pitch units4
Frequency50Hz
Suitable forRelation
Mounting typeREG
Nominal current (In)10A
IP protection)IP20
PermitMeasuring Instruments Directive
Eltako 28465715 DSZ14DRSZ-3x80A RS485 two-way bus three-phase meter
Eltako 28465715 DSZ14DRSZ-3x80A RS485 two-way bus three-phase meter
€187.32
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart