The Restart PRO Autotest residual current circuit breaker (RCCB) carries out an automatic self-test (autotest) at regular intervals, which replaces the manual operation of the test button. The residual current circuit breaker is fully activated during this test without interrupting the system's power supply. If the residual current circuit breaker is triggered, Restart Pro Autotest restores the power supply after an insulation test of the system. If there is a constant system error, no attempt is made to switch it on. The system is checked every 2 minutes by RESTART PRO Autotest. If the system assumes a safe value, RESTART PRO Autotest switches the residual current circuit breaker back on. It will not switch on if an error exists. LEDs and an auxiliary contact signal the operating states. RESTART PRO Autotest can be switched on or off using a simple slide switch. Connection (max): 35 mm² with insulated plug-in protection, feed-in at the top. Compatible with the BUS module.

Property Value
Rated current: 63 A
Number of poles: 2
Rated residual current: 0.03 A
Width in pitch units: 5
Surge current strength: 3 kA
Short-term delayed type: no
Protection class (IP): IP20
Additional devices integrated: Self-test, automatic restart and auxiliary switch
Mounting type: DIN rail
Rated switching current of additional device: 63 A
Fault current type: A
Rated voltage: 230 V
Installation depth: 72 mm
Rated voltage of additional device: 230 V
Frequency: 50 Hz
Control voltage type additional device: AC
Additional devices fitted at the factory: Monitoring unit with automatic restart
Short-circuit strength (Icw): 10 kA
Selective type: no

Characteristics

HABRestart Autotest PRO FI63/0.03A 2P
ManufacturerGewiss
HANGW90913
GTIN8011564804838
Rated residual current0.03A
Rated voltage230V
Rated current63 A
Width in pitch units5
Installation depth72 mm
Residual current typeA
Frequency50Hz
Short circuit strength (Icw)10kA
Short-time delayed typeNo
Mounting typeDIN rail
Number of poles2
IP protection)IP20
Selective typeNo
Surge current strength3kA
Gewiss GW90913 Restart Autotest PRO FI63/0.03A 2P residual current circuit breaker
Gewiss GW90913 Restart Autotest PRO FI63/0.03A 2P residual current circuit breaker
€554.78
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart