Circuit breaker (MCB) in accordance with EN60898-1, with time-delayed thermal overload release and electromagnetic short-circuit release. Up to 2 additional devices can be attached on the left. With label window on the device. Connection (max): flexible 50 mm², rigid 70 mm² with built-in box terminals. With the included conversion kit, the box terminals can be exchanged for a connection for ring cable lugs (hole for M6 screws / width max. 17 mm). For a control line tap, a flat plug connection (width 4.8 mm, thickness 0.5 mm) is integrated for each pole on the incoming and outgoing side. The switching lever can be sealed in the switched-on and off state or can be locked with a lever lock for a padlock.

Property Value
Triggering characteristic: D
Rated current: 63 A
Rated voltage: 400 V
Type of voltage: AC
Frequency: 50 to 60 Hz
Width in pitch units: 1.5
Number of poles (total): 1
Additional equipment possible: yes
Overvoltage category: 4
Installation depth: 72 mm
Protection class (IP): IP20
Rated switching capacity Icn according to EN 60898 at 230 V: 10 kA
Rated switching capacity Icu according to IEC 60947-2 at 230 V: 16 kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V: 4.5 kA
Pollution degree: 2
Switching neutral conductor: no
Number of protected poles: 1
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 6 kV
Ambient temperature during operation: -25 to 60 °C
Connectable conductor cross-section, stranded: 50 mm²
Connectable conductor cross-section, single-wire: 70 mm²

Characteristics

HABHigh performance D-63A 10kA 1-pole 1.5TE
ManufacturerGewiss
HANGW93356
GTIN8011564196360
Connectable conductor cross-section solid70 mm²
Connectable conductor cross-section stranded50 mm²
Number of protected poles1
Trigger characteristicsD
Rated insulation voltage Ui500V
Rated switching capacity Icn according to EN 60898 at 230 V10kA
Rated switching capacity Icu according to IEC 60947-2 at 230 V16kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V4.5kA
Rated voltage400V
Rated impulse withstand voltage Uimp6kV
Rated current63 A
Width in pitch units1.5
Installation depth72 mm
Frequency50 to 60 Hz
Switching neutral conductorNo
Number of poles (total)1
IP protection)IP20
Voltage typeAC
Ambient temperature during operation-25 to 60 °C
Degree of contamination2
Additional equipment possibleYes
Overvoltage category4
Gewiss GW93356 Heavy Duty D-63A 10kA 1-Pole 1.5TE Circuit Breaker
Gewiss GW93356 Heavy Duty D-63A 10kA 1-Pole 1.5TE Circuit Breaker
€89.40
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart