Gewiss GW95488 for an LS switch 125/0.3A 4P 6TE sel. residual current circuit breaker block

In stock
SKU: 662383
€501.49
Into a basketIn the basketGo

Overview

FI circuit breaker block, residual current circuit breaker block independent of mains voltage in selective design [S] according to EN61009-1 Appendix G for combination with circuit breakers of the corresponding series and number of poles. The FI circuit breaker block is mounted on the right-hand side of the circuit breaker and 2 additional devices can be mounted on the left-hand side. After mechanical assembly, the devices are permanently connected to one another. The switching lever can be sealed in the switched-on and off state or can be locked with a lever lock (order accessories separately) for a padlock. With fold-down label plate on the circuit breaker. Connection (max.): flexible 50 mm², rigid 70 mm² with built-in box terminals. With the included conversion kit, the box terminals can be exchanged for a connection for ring cable lugs (hole for M6 screws / width max. 17 mm). The connection screws can be provided with a sealable cover (order accessories separately). The rated switching capacity depends on the installed circuit breaker.

Property Value
Nominal voltage: 400 V
Delay time adjustable: no
Rated residual current adjustable: no
Nominal current: 125 A
Residual current type: A
Number of poles: 4
Rated residual current: 0.3 A
Frequency: 50/60 Hz
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 4 kV
Connectable conductor cross-section, single-wire: 50 mm²
Connectable conductor cross-section, stranded: 50 mm²
False tripping protection: no
With locking device: no
Protection class (IP): IP20
Pollution level: 2
Ambient temperature during operation: -25 to 40 °C

Characteristics

HABF. an LS switch 125/0.3A 4P 6TE sel.
ManufacturerGewiss
HANGW95488
GTIN8011564116696
Connectable conductor cross-section solid50 mm²
Connectable conductor cross-section stranded50 mm²
Rated residual current0.3A
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
False trigger protectionNo
Residual current typeA
Frequency50/60Hz
With locking deviceNo
Nominal voltage400V
Rated current125A
Number of poles4
IP protection)IP20
Ambient temperature during operation-25 to 40 °C
Degree of contamination2
Gewiss GW95488 for an LS switch 125/0.3A 4P 6TE sel. residual current circuit breaker block
Gewiss GW95488 for an LS switch 125/0.3A 4P 6TE sel. residual current circuit breaker block
€501.49
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart