FI circuit breaker block, mains voltage-independent residual current circuit breaker block in accordance with EN61009-1 Appendix G for combination with circuit breakers of the corresponding series and number of poles. The FI circuit breaker block is mounted on the right-hand side of the circuit breaker and 2 additional devices can be mounted on the left-hand side. After mechanical assembly, the devices are permanently connected to one another. The switching lever can be sealed when switched on and off or locked with a lever lock (order accessories separately) for a padlock. With fold-down label on the circuit breaker. Connection (max.): flexible 50 mm², rigid 70 mm² with built-in box terminals. With the included conversion kit, the box terminals can be exchanged for a connection for ring cable lugs (hole for M6 screws / width max. 17 mm). The connection screws can be provided with a sealable cover (order accessories separately). The rated switching capacity depends on the installed circuit breaker. The rated residual current is adjustable. The tripping time is adjustable. The setting potentiometers are located under a sealable, transparent cover.

Property Value
Max. Delay time: 150 ms
Nominal voltage: 400 V
Delay time adjustable: yes
Rated residual current adjustable: yes
Nominal current: 125 A
Residual current type: A
Number of poles: 4
Rated residual current: 0.3 to 3 A
Frequency: 50 Hz
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 4 kV
Connectable conductor cross-section, single-wire: 50 mm²
Connectable conductor cross-section, stranded: 50 mm²
False tripping protection: no
With locking device: no
Degree of protection (IP): IP20
Pollution level: 2
Ambient temperature during operation: -25 to 40 °C

Characteristics

HABFor LS switch 125/0.3-3A 4P 6TE va
ManufacturerGewiss
HANGW95512
GTIN8011564126121
Connectable conductor cross-section solid50 mm²
Connectable conductor cross-section stranded50 mm²
Rated residual current0.3 to 3A
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
False trigger protectionNo
Residual current typeA
Frequency50Hz
With locking deviceNo
Nominal voltage400V
Rated current125A
Number of poles4
IP protection)IP20
Ambient temperature during operation-25 to 40 °C
Degree of contamination2
Gewiss GW95512 for an LS switch 125/0.3-3A 4P 6TE va residual current circuit breaker block
Gewiss GW95512 for an LS switch 125/0.3-3A 4P 6TE va residual current circuit breaker block
€724.07
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart