Catalog

Hager CDS240D residual current circuit breaker 2-pole 40/0, 03A

In stock
SKU: 156239
€40.49
Into a basketIn the basketGo

Overview

Residual current circuit breaker 2-pole 6kA 40A 30mA Type A QuickConnect. Residual current circuit breaker in accordance with EN 61008-1, DIN EN 61008-2-1 and 0664 Part 10 + 11. QuickConnect terminal in accordance with DIN EN 60898-1, 0641-11 at the inlet up to 63 A, contact protection IP2x in accordance with DIN0106 Part 100, blue test button and residual current display. Easy individual removal from the phase busbar assembly. With symbols. Suitable for subsequent installation of additional equipment. Labeling option directly on the device. Suitable for the subsequent installation of additional equipment.

Property Value
Rated voltage: 230 V
Rated current: 40 A
Rated residual current: 0.03 mA
Mounting type: DIN rail
Protection class (IP): IP20
Frequency: 50 Hz
Number of poles: 2
Width in pitch units: 2
Selective type: no
Fault current type: A
Additional equipment possible: yes
Installation depth: 70 mm
Short-circuit strength (Icw): 6 kA
Surge current strength: 0.25 kA
Short-time delayed Type: no
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 4 kV
With locking device: yes
Ambient temperature during operation: -25 to 40 °C
Pollution degree: 2
Connectable conductor cross-section, stranded: 1 to 16 mm²
Connectable conductor cross-section Single-wire: 1 to 25 mm²

Characteristics

ManufacturerHAGER
HANCDS240D
GTIN3250611610830
Connectable conductor cross-section solid1 to 25 mm²
Connectable conductor cross-section stranded1 to 16 mm²
Rated residual current0.03mA
Rated insulation voltage Ui500V
Rated voltage230V
Rated impulse withstand voltage Uimp4kV
Rated current40A
Width in pitch units2
Installation depth70 mm
Residual current typeA
Frequency50Hz
Short circuit strength (Icw)6kA
Short-time delayed typeNo
With locking deviceYes
Mounting typeDIN rail
Number of poles2
IP protection)IP20
Selective typeNo
Surge current strength0.25kA
Ambient temperature during operation-25 to 40 °C
Degree of contamination2
Additional equipment possibleYes
Hager CDS240D residual current circuit breaker 2-pole 40/0, 03A
Hager CDS240D residual current circuit breaker 2-pole 40/0, 03A