Overview

Circuit breaker h3+ P160 LSnI 3P3D 160A 50kA CTC. The molded case circuit breaker in accordance with DIN EN 60947-2 protects the electrical system and networks against overload and short circuit. The tripping curve of the electronic trip can be set using a rotary latching switch. The tripping for the overload current (Ir) and the short-time delayed short-circuit current (Isd) can be set separately. The instantaneous tripping for the short-circuit current Ii is fixed. A standby LED lights up green when the trip is ready for operation and flashes orange when an internal error is detected in the trip. Another LED starts flashing red when I = 105% Ir and lights up red continuously when I > 112% Ir. The three different operating states can be recognized by the position of the knob (ON = top, OFF = bottom, tripped = middle position). A device for locking the switching state in the ON or OFF position is integrated and can be used with a standard padlock without additional accessories. The trigger mechanism can be tested and the main contacts opened using a release button. A hinged cover with a captive quick-release screw allows access to the installation space for optional auxiliary contacts and other triggers. Integrated accessories can be seen and identified via a viewing window without opening the hinged cover. The set tripping curve can be tested and documented using an interface for a diagnostic and configuration tool.

Property Value
Rated continuous current Iu: 160 A
Type of connection for main circuit: Screw connection
Number of poles: 3
Device design: Built-in device, fixed installation technology
Position of connection for main circuit: front
Protection class (IP): IP40
Setting range of the short-time delayed short-circuit release: 86 to 1600 A
Rated voltage: 220 to 690 V
Rated short-circuit breaking current Icu at 400 V, 50 Hz: 50 kA
Suitable for DIN rail mounting: no
Design of the actuating element: toggle
Integrated earth fault protection: no
Motor drive integrated: no
Motor drive optional: no
With trip detector: yes
Complete device with protection unit: yes
DIN rail mounting optional: yes

Characteristics

ManufacturerHAGER
HANHMS160GC
GTIN3250613145774
Connection type main circuitScrew connection
Design of the actuating elementGag
Rated continuous current Iu160A
Rated ultimate short-circuit breaking current Icu at 400 V, 50 Hz50kA
Rated voltage220 to 690 V
Setting range of the short-time delayed short-circuit release86 to 1600 A
Suitable for DIN rail mountingNo
Device typeBuilt-in device Fixed installation technology
DIN rail mounting optionalYes
Integrated earth fault protectionNo
Complete device with protection unitYes
With trip detectorYes
Motor drive integratedNo
Motor drive optionalNo
Number of poles3
Position of the connection for main circuitIn front
IP protection)IP40
Hager HMS160GC h3+ P160 3P3D 160A 50kA circuit breaker
Hager HMS160GC h3+ P160 3P3D 160A 50kA circuit breaker
€797.82
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart