Hager HNT160JR h3+ P250 3P3D 160A 40kA circuit breaker

In stock
SKU: 432124
€1,093.42
Into a basketIn the basketGo

Overview

Circuit breaker h3+ P250 LSI 3P3D 160A 40kA FTC. The molded case circuit breaker in accordance with DIN EN 60947-2 protects the electrical system and networks against overload and short circuit. The tripping curve of the electronic release can be set using a rotary latching switch. The triggers for the overload current (Ir), the short-time delayed short-circuit current (Isd) and the undelayed short-circuit protection (Ii) as well as the time delay tr for overload and the time delay tsd for short-time delayed short-circuit release can be set separately. In addition, the tripping curve can be adjusted inversely proportionally using an activatable I²t function between the short-circuit currents Ii and Isd and the short-time delayed and undelayed tripping time. The standby LED lights up green when the release is ready for operation and flashes orange when an internal error is detected in the release. The LED for the overcurrent indicator starts to flash red when I = 105% Ir, and lights up red continuously when I > 112% Ir. Another LED signals the overtemperature in the trip unit. This lights up red when 105°C is exceeded internally. The three different operating states can be identified by the position of the toggle (ON = top, OFF = bottom, triggered = middle position). A device for locking the switching state in the ON or OFF position is integrated and can be used with a standard padlock without additional accessories. The trigger mechanism can be tested and the main contacts opened using a trigger button. A hinged cover with a captive quick-release screw allows access to the installation space for optional auxiliary contacts and other triggers. Integrated accessories can be recognized and identified via the viewing window without opening the hinged cover. A potential-free alarm contact for the switch-off warning in the event of a risk of shutdown due to overload is integrated as standard. This is closed when I > 90% Ir. This is indicated by an additional LED. It lights up orange when the contact is closed. The set tripping curve can be tested and documented using an interface for a diagnostic and configuration tool.

Property Value
Rated continuous current Iu: 160 A
Type of connection for main circuit: Screw connection
Number of poles: 3
Device design: Built-in device, fixed installation technology
Position of connection for main circuit: front
Protection class (IP): IP40
Setting range of the short-time delayed short-circuit release: 86 to 1600 A
Rated voltage: 220 to 690 V
Rated short-circuit breaking current Icu at 400 V, 50 Hz: 40 kA
Suitable for DIN rail mounting: no
Design of the actuating element: toggle
Integrated earth fault protection: no
Motor drive integrated: no
Motor drive optional: yes
With trip detector: yes
Complete device with protection unit: yes
DIN rail mounting optional: yes

Characteristics

ManufacturerHAGER
HANHNT160JR
GTIN3250613176761
Connection type main circuitScrew connection
Design of the actuating elementGag
Rated continuous current Iu160A
Rated ultimate short-circuit breaking current Icu at 400 V, 50 Hz40kA
Rated voltage220 to 690 V
Setting range of the short-time delayed short-circuit release86 to 1600 A
Suitable for DIN rail mountingNo
Device typeBuilt-in device Fixed installation technology
DIN rail mounting optionalYes
Integrated earth fault protectionNo
Complete device with protection unitYes
With trip detectorYes
Motor drive integratedNo
Motor drive optionalYes
Number of poles3
Position of the connection for main circuitIn front
IP protection)IP40
Hager HNT160JR h3+ P250 3P3D 160A 40kA circuit breaker
Hager HNT160JR h3+ P250 3P3D 160A 40kA circuit breaker
€1,093.42
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart