Catalog

Hager MCN202 circuit breaker C2A 2-pole 6kA

In stock
SKU: 157676
€56.91
Into a basketIn the basketGo

Overview

Circuit breaker 2-pole 6kA C characteristic 2A 2 modules. Circuit breaker in accordance with DIN0641 part 11/8.92, contact protection IP2x in accordance with DIN0106 part 100 with symbol. Circuit breaker with time-delayed thermal release for overload protection and electromagnetic release for short-circuit protection. Suitable for the subsequent installation of additional equipment. Labelling option directly on the device and individual removal from the phase rail assembly by unlocking the quick-release top hat rail fastening.

Property Value
Triggering characteristic: C
Rated current: 2 A
Rated voltage: 400 V
Type of voltage: AC
Frequency: 50 to 60 Hz
Width in pitch units: 2
Number of poles (total): 2
Energy limitation class: 3
Additional equipment possible: yes
Overvoltage category: 3
Installation depth: 70 mm
Protection class (IP): IP20
Rated switching capacity Icu according to IEC 60947-2 at 400 V: 10 kA
Rated switching capacity Icn according to EN 60898 at 400 V: 6 kA
Pollution level: 2
Switching neutral conductor: no
Number of protected poles: 2
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 4 kV
Ambient temperature during operation: -25 to 70 °C
Connectable conductor cross-section stranded: 1 to 25 mm²
Connectable conductor cross-section single-wire: 1 to 35 mm²

Characteristics

ManufacturerHAGER
HANMCN202
GTIN3250614311246
Connectable conductor cross-section solid1 to 35 mm²
Connectable conductor cross-section stranded1 to 25 mm²
Number of protected poles2
Trigger characteristicsC
Rated insulation voltage Ui500V
Rated switching capacity Icn according to EN 60898 at 400 V6kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V10kA
Rated voltage400V
Rated impulse withstand voltage Uimp4kV
Rated current2 A
Width in pitch units2
Installation depth70 mm
Energy limitation class3
Frequency50 to 60 Hz
Switching neutral conductorNo
Number of poles (total)2
IP protection)IP20
Voltage typeAC
Ambient temperature during operation-25 to 70 °C
Degree of contamination2
Additional equipment possibleYes
Overvoltage category3
Hager MCN202 circuit breaker C2A 2-pole 6kA
Hager MCN202 circuit breaker C2A 2-pole 6kA
€56.91
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart