BEKA control panel for 50 radio detectors, white. Bidirectional radio fire detection system for preventive fire protection for the construction and operation of day care facilities for children, small homes, accommodation facilities, hotels with more than 12 beds up to 60 beds for which no BMZ is required, as well as for residential facilities for seniors, disabled people or other special types of housing. The bidirectional radio transmission is transmitted using two separate radio bands with frequency interference in the 434 MHz range with 20 frequencies and in the 868 MHz range with 4 frequencies. A maximum of 64 automatic or manual devices can be controlled and evaluated in the 8 detection areas, which are integrated with automatic sensor head recognition and push-button learning procedures (max. 64 devices: 50 detectors, 14 radio indoor sirens or 10 repeaters). The control panel has the option of connecting alarm, fault, collective alarm reset with 3 switching inputs, day/night operation and has 4 relay and open collector switching outputs each for the external control of other display devices. The control panel checks the transmission path of the integrated detectors and components bidirectionally within 300 seconds and thus ensures a close-meshed transmission path check. Status/fault or alarm messages are shown on the control panel display in plain text with location/time information in combination with the 3-color display as optical and additional acoustic signal or forwarded to 8 defined recipients via SMS or email using the optional GSM module RFW066D. The last 1000 events can be viewed chronologically. During commissioning, the configuration is carried out manually on the control panel display or using the configuration tool, text entries and other settings as well as archiving can be imported or downloaded to the control panel via the USB or RS232 interface. After the initial installation is complete, an automatic overall check of the entire system is carried out and sent via USB interface, SD card or, optionally, with the GSM module, by email in the form of a handover/commissioning protocol. With the optional GSM module, the control panel can forward a status report on the degree of contamination, battery and system status of the individual integrated components by email to a defined recipient at the set maintenance request interval after confirmation by a trained person. In maintenance mode, the results of the maintenance can be transmitted via USB interface, SD card or, optionally, by email and saved separately and sent as a maintenance protocol. Access to the customer level is optionally possible via a PIN code to display the day/night function or to temporarily deactivate detection areas, as well as for basic settings of the customer level, resetting fault and alarm messages or optionally for forwarding the maintenance request by email or SMS. Access to the installer level is via a PIN code, whereby the main setting features of the system can only be configured or changed by the installer. The day/night setting, code change and other important configuration or setup settings can be made at the installer level. Note: The RFA400D emergency power battery is not included in the scope of delivery. Approval: DIN EN 54-2, DIN EN 54-4, DIN EN 54-25.
Property | Value |
Number of alarm groups: | 8 |
Operating voltage: | 230 V |
Width: | 220 mm |
Bus-capable: | no |
Wireless connection: | yes |
Height: | 325 mm |
Integrated Dialer: | no |
With power supply: | yes |
Integrated emergency power supply: | yes |
External interface: | yes |
Depth: | 88 mm |
Mounting type: | Structure |
Number of detector addresses: | 30 |
Current consumption: | 50 mA |
Addressable: | no |