Catalog

Legrand 409542 Circuit breaker DX3 D125A 4P 10KA 6M

In stock
SKU: 244178
€592.33
Into a basketIn the basketGo

Overview

Legrand miniature circuit breaker DX3 according to EN 60947-2, 4-pole, D characteristic, rated current In 125 A, rated switching capacity 10 kA according to EN 60898-1, rated voltage Un 400 VAC, rated frequency 50/60 Hz, fastening on top hat rail EN 60715 using two snap-in quick fasteners, clear information on the front of each device, clear switch position indicator red/green, with labeling window, with protection against misplacement for safe insertion of the conductor into the elevator terminal, attachment of auxiliary devices possible. Circuit breakers with D characteristics are intended for line protection in power circuits with very high inrush currents (e.g. welding transformers).

Property Value
Tripping characteristic: D
Rated current: 125 A
Rated voltage: 400 V
Type of voltage: AC
Frequency: 50 to 60 Hz
Width in pitch units: 6
Number of poles (total): 4
Additional equipment possible: yes
Installation depth: 47 mm
Protection class (IP): IP20
Rated switching capacity Icu according to IEC 60947-2 at 230 V: 32 kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V: 16 kA
Rated switching capacity Icn according to EN 60898 at 400 V: 10 kA
Pollution level: 2
Switching neutral conductor: yes
Number of protected poles: 4
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 4 kV
Ambient temperature during operation: -25 to 70 °C
Connectable conductor cross-section stranded: 6 to 50 mm²
Connectable conductor cross-section single-wire: 6 to 70 mm²

Characteristics

Insert Module TypeLight switch covers
ManufacturerLEGRAND
HAN409542
GTIN3245064095426
Connectable conductor cross-section solid6 to 70 mm²
Connectable conductor cross-section stranded6 to 50 mm²
Number of protected poles4
Trigger characteristicsD
Rated insulation voltage Ui500V
Rated switching capacity Icn according to EN 60898 at 400 V10kA
Rated switching capacity Icu according to IEC 60947-2 at 230 V32kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V16kA
Rated voltage400V
Rated impulse withstand voltage Uimp4kV
Rated current125A
Width in pitch units6
Installation depth47 mm
Frequency50 to 60 Hz
Switching neutral conductorYes
Number of poles (total)4
IP protection)IP20
Voltage typeAC
Ambient temperature during operation-25 to 70 °C
Degree of contamination2
Additional equipment possibleYes
Legrand 409542 Circuit breaker DX3 D125A 4P 10KA 6M
Legrand 409542 Circuit breaker DX3 D125A 4P 10KA 6M
€592.33
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart