Circuit breaker NG125L, 1P, 16A, D-characteristic. Product range: NG125 - Range: Acti 9 - Product or component type: Circuit breaker - Device short name: NG125L - Network type: AC, DC - Trip unit technology: thermomagnetic - Interrupting capacity: 100 kA Icu according to EN/IEC 60947-2 - 110-130V AC 50/60 Hz, 12.5 kA Icu according to EN/IEC 60947-2 - 380-415V AC 50/60 Hz, 36 kA Icu according to EN/IEC 60947-2 - 144V DC, 50 kA Icu according to EN/IEC 60947-2 - 12V DC, 50 kA Icu according to EN/IEC 60947-2 - 125V DC, 50 kA Icu according to EN/IEC 60947-2 - 220-240V AC 50/60 Hz.

Property Value
Tripping characteristic: D
Rated current: 16.0 A
Rated voltage: 400.0 V
Type of voltage: AC/DC
Frequency: 50.0 to 60.0 Hz
TE: 1.5
Number of poles (total): 1.0
Additional equipment possible: yes
Overvoltage category: 4.0
Installation depth: 47.0 mm
Protection class (IP): IP20
Rated switching capacity Icu according to IEC 60947-2 at 230 V: 50.0 kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V: 12.5 kA
Degree of pollution: 3.0
Switching neutral conductor: no
Number of protected poles: 1.0
Flush-mounted installation: no
Rated insulation voltage Ui: 690.0 V
Rated impulse withstand voltage Uimp: 8.0 kV
Ambient temperature during operation: -30.0 to 70.0 °C
Connectable conductor cross-section, stranded: 1.0 to 35.0 mm²
Connectable conductor cross-section, single-wire: 1.5 to 50.0 mm²
Explosion-proof: no

Characteristics

Flush-mounted installationNo
HAB18831
ManufacturerSchneider Electric
HAN18831
GTIN3303430188315
Connectable conductor cross-section solid1.5 to 50.0 mm²
Connectable conductor cross-section stranded1.0 to 35.0 mm²
Number of protected poles1.0
Trigger characteristicsD
Rated insulation voltage Ui690.0V
Rated switching capacity Icu according to IEC 60947-2 at 230 V50.0kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V12.5kA
Rated voltage400.0V
Rated impulse withstand voltage Uimp8.0kV
Rated current16.0A
Installation depth47.0 mm
Explosion-proofNo
Frequency50.0 to 60.0 Hz
Switching neutral conductorNo
Number of poles (total)1.0
IP protection)IP20
Voltage typeAC/DC
TE1.5
Ambient temperature during operation-30.0 to 70.0 °C
Degree of contamination3.0
Additional equipment possibleYes
Overvoltage category4.0
Schneider Electric 18831 circuit breaker
Schneider Electric 18831 circuit breaker
€86.38
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart