Residual current circuit breaker, 2-pole, type A, In: 125 A, 100 mA, Un AC: 230 V The residual current circuit breaker is the residual current device for contact protection. The patented residual current devices from Siemens are an important component of the SENTRON protective devices for electrical installations, because they prevent life-threatening electrical accidents by safely switching off dangerous residual currents to earth. Electrically ignited fires can be prevented before they even start. Whether through direct contact with parts that are live during operation or through indirect contact with equipment - protection is achieved primarily through rapid switching off. The residual current circuit breakers are characterized by: 1. Comprehensive protection for people and property against electric shock 2. Whether sinusoidal alternating residual currents or smooth direct residual currents - Siemens offers the right type for all requirements as well as special versions 3. Be protected in accordance with standards: All residual current circuit breakers comply with the provisions of DIN4. Optimum technology for your safety - only from Siemens www.siemens.de/fehlerstromschutz. Siemens offers a comprehensive portfolio of protection, switching, measuring and monitoring devices, distribution systems as well as switches and sockets for safe, efficient electrical infrastructure in buildings and industry.

Property Value
Rated voltage: 230 V
Rated current: 125 A
Rated residual current: 0.1 mA
Frequency: 50 Hz
Number of poles: 2
Width in Division units: 2
Selective type: no
Residual current type: A
Additional devices possible: yes
Installation depth: 70 mm
Short-circuit strength (Icw): 10 kA
Surge current strength: 1 kA
Short-time delayed type: no
With locking device: yes
Ambient temperature during operation: -25 to 45 °C
Connectable conductor cross-section, stranded: 1.5 to 50 mm²
Connectable conductor cross-section, single-wire: 1.5 to 50 mm²

Characteristics

HAB5SM3415-6KK 125/0.1A 1+N-pole IFN 230V
ManufacturerSIEMENS
HAN5SM3415-6KK
GTIN4001869272733
Connectable conductor cross-section solid1.5 to 50 mm²
Connectable conductor cross-section stranded1.5 to 50 mm²
Rated residual current0.1mA
Rated voltage230V
Rated current125A
Width in pitch units2
Installation depth70 mm
Residual current typeA
Frequency50Hz
Short circuit strength (Icw)10kA
Short-time delayed typeNo
With locking deviceYes
Number of poles2
Selective typeNo
Surge current strength1kA
Ambient temperature during operation-25 to 45 °C
Additional equipment possibleYes
Siemens 5SM3415-6KK residual current circuit breaker 125/0.1A 1+N-pole IFN 230V
Siemens 5SM3415-6KK residual current circuit breaker 125/0.1A 1+N-pole IFN 230V
€240.15
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart