Residual current circuit breaker, 4-pole, type A, In: 80 A, 300 mA, Un AC: 400 V The residual current circuit breaker is the residual current device for contact protection. The patented residual current devices from Siemens are an important part of the SENTRON protective components for electrical installations, because they prevent life-threatening electrical accidents by safely switching off dangerous residual currents to earth. Electrically ignited fires can be prevented before they even start. Whether through direct contact with parts that are live during operation or through indirect contact with equipment - protection is achieved primarily through rapid switching off. The Siemens residual current circuit breakers 5SV are characterized above all by: 1. Comprehensive protection for people and property against electric shock 2. Whether sinusoidal alternating residual currents or smooth direct residual currents - Siemens offers the right type and special versions for all requirements 3. Reliable safety during installation thanks to the grip and contact protection included as standard 4. Tool-free removal from the top hat rail or from the busbar assembly thanks to convenient manual slide operation 5. Data matrix code on the front of the device provides all information about the residual current circuit breaker quickly and easily 6. Be protected in accordance with standards: The residual current circuit breakers comply with the provisions of DIN7. Optimum technology for your safety - only from Siemens www.siemens.de/fehlerstromschutz. Siemens offers a comprehensive portfolio of protection, switching, measuring and monitoring devices, distribution systems as well as switches and sockets for safe, efficient electrical infrastructure in buildings and industry.

Property Value
Rated voltage: 400 V
Rated current: 80 A
Rated residual current: 0.3 mA
Frequency: 50 Hz
Number of poles: 4
Width in Division units: 4
Selective type: no
Residual current type: A
Additional devices possible: yes
Installation depth: 70 mm
Short-circuit strength (Icw): 10 kA
Surge current strength: 1 kA
Short-time delayed type: no
With locking device: yes
Ambient temperature during operation: -25 to 45 °C
Connectable conductor cross-section, stranded: 0.75 to 35 mm²
Connectable conductor cross-section, single-wire: 0.75 to 35 mm²

Characteristics

HAB5SV3647-6 80/0.3A 4-pole
ManufacturerSIEMENS
HAN5SV3647-6
GTIN4001869427874
Connectable conductor cross-section solid0.75 to 35 mm²
Connectable conductor cross-section stranded0.75 to 35 mm²
Rated residual current0.3mA
Rated voltage400V
Rated current80A
Width in pitch units4
Installation depth70 mm
Residual current typeA
Frequency50Hz
Short circuit strength (Icw)10kA
Short-time delayed typeNo
With locking deviceYes
Number of poles4
Selective typeNo
Surge current strength1kA
Ambient temperature during operation-25 to 45 °C
Additional equipment possibleYes
Siemens 5SV3647-6 residual current circuit breaker 80/0.3A 4-pole
Siemens 5SV3647-6 residual current circuit breaker 80/0.3A 4-pole
€413.78
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart