Catalog

Eaton FRBM4-C32/3N/003-A 3-pole 32A 30mA FI/LS switch, 171002

In stock
SKU: 479459
€167.50
Into a basketIn the basketGo

Overview

High-quality residual current circuit breaker/circuit breaker combination independent of mains voltage, contact position indicator red-green, clamping aid - rear plug protection, tri-stable locking slide - enables removal from an existing busbar assembly, extensive range of accessories can be retrofitted, large selection of rated residual currents, rated currents up to 40A, tripping characteristics B, C, D, rated switching capacity 10kA, suitable for use outdoors (construction site power and outdoor distributors) down to -25°C

PropertyValue
Tripping characteristic:C
Rated current:32 A
Rated residual current:0.03 A
Rated voltage:415 V
Frequency:50 Hz
Number of poles (total):4
Width in modular spacing:4
Residual current type:A
Installation depth:75.5 mm
Rated breaking capacity according to IEC 60947-2:4.5 kA
Surge current strength:0.25 kA
Protection class (IP):IP20
Energy limitation class:3
Overvoltage category:3
Pollution degree:2
Switching neutral conductor:yes
Number of protected poles:4
Voltage type:AC
False tripping protection:no
Rated insulation voltage Ui:500 V
Rated impulse withstand voltage Uimp:4 kV
Rated breaking capacity according to EN 61009:4.5 kA
Rated short-circuit breaking capacity Icn according to EN 61009-1:4.5 kA
Shutdown characteristic:instantaneous
With locking device:no
Ambient temperature during operation:-25 to 40 °C
Connectable conductor cross-section, single-wire:1 to 25 mm²
Connectable Stranded conductor cross-section:1 to 25 mm²

Characteristics

Shutdown characteristicsWithout delay
Rated short-circuit breaking capacity Icn according to EN 61009-14.5 kA
HABFRBM4-C32/3N/003-A 3-pin 32A 30mA
ManufacturerEaton
HAN171002
GTIN4015081675067
Connectable conductor cross-section solid1 to 25 mm²
Connectable conductor cross-section stranded1 to 25 mm²
Number of protected poles4
Trigger characteristicsC
Rated breaking capacity according to EN 610094.5kA
Rated breaking capacity according to IEC 60947-24.5kA
Rated residual current0.03A
Rated insulation voltage Ui500V
Rated voltage415V
Rated impulse withstand voltage Uimp4kV
Rated current32 A
Width in pitch units4
Installation depth75.5 mm
Energy limitation class3
False trigger protectionNo
Residual current typeA
Frequency50Hz
With locking deviceNo
Switching neutral conductorYes
Number of poles (total)4
IP protection)IP20
Voltage typeAC
Surge current strength0.25kA
Ambient temperature during operation-25 to 40 °C
Degree of contamination2
Overvoltage category3
Eaton FRBM4-C32/3N/003-A 3-pole 32A 30mA FI/LS switch, 171002
Eaton FRBM4-C32/3N/003-A 3-pole 32A 30mA FI/LS switch, 171002
€167.50
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart