Catalog

Hager SPB315 T2 3P 40kA TNC fault indication surge arrester

In stock
SKU: 770346
€163.25
Into a basketIn the basketGo

Overview

Surge arrester T2 3P 40kA TNC defect indication + contact. Type 2 surge arrester in 3+0 circuit, for protecting three-phase TN-C systems. Consists of a triple base element and three protective plugs with temperature-monitored high-performance varistor with disconnection device. Optical defect indication on the plugs in the event of overload. Changeover contact for remote defect indication. Connections for the active conductors from below, for earth/PE and remote indication contact from above. Biconnect terminals for connecting round conductors and wiring bridges. Labeling option on the base element.

Property Value
Protection level: 1.35 kV
Nominal discharge current (8/20): 20 kA
Highest continuous voltage AC: 275 V
Nominal voltage AC: 400 V
Protection level LN: 1.35 kV
Mounting type: DIN rail TH35
Size: 3 TE
Signaling on the device: optical
With remote signaling contact: yes
Test class type 2: yes
Max. conductor cross-section flexible (fine-stranded): 25 mm²
Max. Conductor cross-section rigid (single/multi-wire): 35 mm²
Integrated backup fuse: no
Protection class (IP): IP20
Network type TN: yes
Network type TN-C: yes
Network type TN-CS: no
Network type TN-S: no
Network type TT: no
Network type other: no
Number of conductors (excluding earth): 3
Short-circuit strength (Isccr): 25 kA
Max. discharge current (8/20): 40 kA

Characteristics

Max. conductor cross-section rigid (single/multi-wire)35 mm²
Max. conductor cross-section flexible (fine-stranded)25 mm²
Protection level1.35 kV
With remote signaling contactYes
Number of conductors (excluding earth)3
Network form TTNo
Network type TN-SNo
Max. discharge current (8/20)40 kA
Test class type 2Yes
Network form TNYes
Network type TN-CYes
Network type TN-C-SNo
Short circuit strength (Isccr)25 kA
Protection level L-N1.35 kV
Integrated backup fuseNo
HABSPB315 T2 3P 40kA TNC fault indicator
ManufacturerHAGER
HANSPB315
GTIN3250615514899
Size3 HP
Highest continuous voltage AC275V
Mounting typeDIN rail TH35
Nominal discharge current (8/20)20kA
Nominal voltage AC400V
IP protection)IP20
Signaling on the deviceOptical
Hager SPB315 T2 3P 40kA TNC fault indication surge arrester
Hager SPB315 T2 3P 40kA TNC fault indication surge arrester
€163.25
Into a basketIn the basketGo
Delivery in Europe
We will deliver your order to all European cities.
In cash, by bank card or online
We are located
8200-121 Albufeira.R. Dr. Diogo Leote 35.
24 hours
We will send the order within 24 hours.
HomeCatalogSearchProfile0Cart