Bus input module for connecting 8 wired opening detectors (NC) or 8 detection lines (with up to 5 magnetic contacts) to the System 9000 bus. Occupies eight addresses in the system when registering. Can be set to 8 detection lines or alternatively to 7 detection lines and a resistance-monitored sabotage line. Lines can be individually set to respond to burglary or panic. Occupies eight addresses in the system. Length of a detection line max. 100m. Operating voltage via bus. Quiescent current consumption: 5mA, I-calc =10mA. Can be installed in a flush-mounted box, in the 9000BD1/2 mounting box or directly in the control panel. Dimensions: 50 x 38 x 14mm. Delivery includes 8 pcs. 1kOhm resistors.