Automotive industry, industrial and machine tools, handling machines, In hose packages of articulated arm robots and for use in gantry robots, In energy chains or mobile machine parts, Space-saving due to small cable diameters, Durable in rough use thanks to resistant PUR sheath material, Insensitive to contact with many mineral oil-based lubricants, diluted acids, aqueous alkaline solutions and other chemical media, Wide temperature range for use in harsh climatic conditions, Copper shielding to protect against electromagnetic interference, Fine or ultra-fine stranded wire made of bare copper wires, Core insulation made of TPE, Cores twisted in layers, Wrapping made of PTFE tape, Shielding made of tinned copper wires, Sheath made of polyurethane, black (similar to RAL 9005), When used in energy chains: Please observe installation guidelines Appendix T3, For travel distances up to 10 m, Designed for up to 5 million Torsion cycles, abrasion-resistant and notch-resistant, flexible at low temperatures, increased oil resistance, low-adhesion surface, flame-retardant,
Property | Value |
Number of cores: | 25 |
Conductor nominal cross-section: | 0.25 mm² |
Sheath color: | black |
Outer diameter approx.: | 11.1 mm |
Conductor class: | Class 5 = fine-wire |
Stranding element: | no |
Material of the core insulation: | other |
Core marking: | color |
Protective conductor: | no |
Shield over stranding element: | without |
Shield over stranding: | other |
Support element: | without |
Sheath material: | Polyurethane (PUR) |
Torsion protection: | no |
Halogen-free according to EN 60754-1/2: | no |
Flame-retardant: | according to EN 60332-1-2 |
Low smoke according to EN 61034-2: | no |
Cold-resistant according to EN 60811-504+505+506: | yes |
Oil-resistant according to EN 60811-404: | yes |
Permissible external cable temperature during assembly/handling: | -40 to 80 °C |
Permissible Cable external temperature after installation without vibration: | -50 to 80 °C |
Nominal voltage U0: | 300 V |
Nominal voltage U: | 48 V |
AWG size: | 24 |
Conductor nominal cross-section (AWG): | 24 kcmil |
Specification of core insulation: | other |
Specification of sheath material: | other |
Fire behavior class according to EN 13501-6: | without |
Smoke development class according to EN 13501-6: | without |
Drip behaviour class according to EN 13501-6: | without |
Acid development class according to EN 13501-6: | without |
Shape: | round |
Min. permissible bending radius, flexible use with forced guidance: | 166.5 mm |
Min. permissible bending radius, stationary use/fixed installation: | 44.4 mm |