For use in rail vehicles, for fixed installation and for applications where limited movement is to be expected, Suitable for connecting lights, heating devices, switching devices, junction boxes and power supplies, Can also be used in oily environments and areas with increased ambient temperatures, Good chemical resistance, Robust against mechanical influences in harsh environmental conditions, Extended temperature range, Reduced fire spread to protect people and property in the event of a fire, Tinned copper strand, fine-wire, Insulation: Electron beam cross-linked polymer compound EI 109, Color: Black or green-yellow, Also available in red and blue, EN 50264-3-1 Type M, EN 45545-2 HL1, HL2, HL3, NF F 16-101 - Classification: C / F0 (fire propagation / smoke), Compliant with NFPA 130, Fire behavior according to EN/IEC: - Halogen-free according to EN 60754-1 - No corrosive gases according to EN 60754-2 - No fluorine according to EN 60684-2 - No toxic gases according to EN 50305 - Low smoke density according to EN 61034-2 - Flame retardant according to EN 60332-1-2 - No fire propagation, Chemical properties: - Oil resistant according to EN 50264-3-1 - Fuel resistant according to EN 50264-3-1 - Acid resistant according to EN 50264-3-1 - Alkali resistant according to EN 50264-3-1 - Ozone resistant according to EN 50264-3-1/ EN 50305), Fire behaviour according to NF: - Toxicity of the combustion gases according to NF X 70-100 - Low smoke density according to NF X 10-702 - No fire propagation according to NF C 32-070, cat. C1 and C2, current carrying capacity according to EN 50355, Appendix A,
Property | Value |
Number of cores: | 1 |
Conductor nominal cross-section: | 2.5 mm² |
Outer diameter approx.: | 3.4 mm |
Conductor shape: | round |
Conductor class: | Cl.5 = fine-stranded |
Conductor material: | copper |
Material of the core insulation: | other |
Core marking: | without |
Protective conductor: | no |
Sheath material: | without |
Nominal voltage U: | 1 kV |
Nominal voltage U0: | 0.6 kV |
Layered sheath: | no |
Fiber optic elements: | no |
Inner conductive layer: | no |
Outer conductive layer: | no |
Shield: | no |
Drain wire: | no |
Lead sheath: | no |
Concentric conductor: | without |
Reinforcement: | no |
Conductive coating: | no |
Shield Longitudinally watertight: | no |
Halogen-free according to EN 60754-1/2: | yes |
Halogen-free according to IEC 60754-2: | yes |
Flame-retardant: | according to EN 60332-3-24 |
Low smoke according to EN 61034-2: | yes |
Low smoke according to IEC 61034-2: | yes |
Insulation integrity according to IEC 60331: | no |
Insulation integrity: | no |
Functional integrity: | no |
Oil resistant according to IEC 60811-404: | yes |
Maximum permitted conductor temperature: | 120 °C |
Permissible external cable temperature during assembly/handling: | -35 to 90 °C |
Permissible Cable external temperature after installation without vibration: | -45 to 120 °C |
Conductor surface: | tinned |
Min. permissible bending radius, stationary use/permanently installed: | 10.2 mm |