Width: 1000mm, Weight: 229kg, Height: 2220mm, Max. operating pressure: 3bar, Max. additional electric heating: 48kW, With thermal insulation: no, Depth: 1140mm, Water content: 1500l, Buffer storage for hydraulic decoupling of the volume flows of heat pumps and heating circuit. The storage tank serves as a system separation storage to extend the heat pump running time and to partially bridge tariff shutdown times. Optional addition by equipping the flange opening and 6 screw-in sockets. - Flange connections DN 80 for heat pump and heating circuit - Use in conjunction with large heat pumps, e.g. from WPF 40 - Flange opening 280 mm with blind flange for optional use of WTW, WTFS and FCR electric heating flange - Can be combined with up to two heat generators and two electric screw-in heaters Without thermal insulation, this must be ordered separately as special accessory WD1000/1500 SBP!